翻訳と辞書
Words near each other
・ Ei koskaan
・ Ei mechanism
・ EI Niš
・ Ei roosid
・ Ei Samay Sangbadpatra
・ Ei Station
・ Ei, Kagoshima
・ EI-END
・ Ei-ichi Negishi
・ Ei-Q
・ Ei-Ōkawa Station
・ EI24
・ Ei8ht
・ EIA
・ Eia
EIA RF Connectors
・ EIA standards
・ EIA-530
・ EIA-608
・ EIA-649 National Consensus Standard for Configuration Management
・ EIA/TIA-662
・ EIAJ connector
・ EIAJ MTS
・ EIAJ-1
・ Eial Strahman
・ EIAO
・ Eiao
・ Eiao Island Nature Reserve
・ Eiao Marquesan warbler
・ Eiao monarch


Dictionary Lists
翻訳と辞書 辞書検索 [ 開発暫定版 ]
スポンサード リンク

EIA RF Connectors : ウィキペディア英語版
EIA RF Connectors

EIA RF Connectors are used to connect two items of high power radio frequency rigid or semi-rigid (flexline) coaxial transmission line. Typically these are only required in very high power transmitting installations (10s of kW to MW) where the feedline diameters may be several inches. One side of the connection is denoted as a male connection, or bullet, while the other side is denoted as the female connection, or cup. The Electronic Industries Alliance (EIA) are responsible for a number of standard imperial connector sizes.
==Dimensions==
The flange design, inner and outer conductor dimensions are standardized, by EIA, in the RS-225, 50 Ω (ohm), and RS-259, 75 Ω, standards. They are commonly referred to by the outer diameter of the outer conductor in fractional inches. Sizes covered under these two standards range from 3/8 to 6 1/8 inch outside diameter (OD) for 50 Ω and 3/8 to 3 1/8 inch OD for 75 Ω.
Peak pulse power handling, driven by voltage breakdown, is more or less frequency independent for any given size (and can be deduced by assuming ~300 V RMS per mm of inner to outer spacing), but the average power, limited by losses heating the centre conductors, increases approximately with the square root of the operating frequency. Commonly the limit is quoted as that dissipation that will raise the inner temperature to 100 °C when the outer is maintained constant at +40 °C. Field failures can occur at power levels well below this if the central bullet connections are not making uniform positive contact and free of contamination. Conversely the average power ratings can be significantly exceeded if there is forced air flow either through the inner conductor or through the void between the inner and outer conductors. Many years ago, the two RS standards were considered obsolete by EIA. Only recently (until 2007) there has been an effort by manufacturers in the US to update these standards.

抄文引用元・出典: フリー百科事典『 ウィキペディア(Wikipedia)
ウィキペディアで「EIA RF Connectors」の詳細全文を読む



スポンサード リンク
翻訳と辞書 : 翻訳のためのインターネットリソース

Copyright(C) kotoba.ne.jp 1997-2016. All Rights Reserved.